GSH-60

Automatic HPLC HbA1c Analyzer.
  • Goldsite

Availability:

1



DESIGN FOR EFFICIENCY AND PRECISION

Up to 60 tests per hour. STAT position supported



2



EXCELLENT PRECISION: CV<1.5%

JCTLM reference measurement method- ion exchange high performance liquid chromatography (HPLC)


PERFORMANCE COMPARISON: GSH-60 VS.Tosoh HLC -723G8

3



SELF-DEVELOPED CONSUMABLES AND REAGENTS

Excellent performance and stable quality

Highly reusable chromatographic columns and filters

Comprehensive quality control system for reagents

Compatible quality control products and calibrators


Cat No. Description Pack Size  Unit
1 Reagent Kit   (350 Tests)


GH1800 HbA1c   Elution Buffer A 800 mL 1
GH2400 HbA1c   Elution Buffer B 400 mL 1
GH3400 HbA1c   Elution Buffer C 400 mL 1
GHL2000 Hemolysis 2000 mL 2
GH001 Filter 1 2
2 Column


GH091 Test   Column  1 (10K test)  1

3 Calibrator &   Control
HBBZGH HbA1c   Calibrator 2*0.5mL 1
HBDM072 HbA1c   Control 0.5mL 1
HBDM072H HbA1c   Control High Level 0.5mL 1



3 Performance


  • Excellent precision: CV≤1.5%

  • Broader test range: 2.8%~18.4%

  • Report multiple glycation components to provide more comprehensive clinical reference


1 Easy Maintenance


  • Automated daily maintenance

  • Power-saving auto Stand-by function

  • Utilize 4~12 Mpa high pressure pump which offers steady output and minimizes pipe blockage


2 High Efficiency


  • Up to 60 tests per hour. STAT position supported.

  • Direct whole blood testing

  • Cap piercing and no sample pre-treatment

  • 110 sample positions with automatic loading function.

  • Automatic identification of sample tube type.

  • Userfriendly 20° flippable touch screen






Prevention and monitoring of chronic

complications of diabetes mellitus

Differentiation

of stress hyperglycemia

from diabetes mellitus

Diagnosis of neonatal and gestational diabetes mellitus

Early screening and diagnosis of diabetes mellitus

Evaluation of the effectiveness of blood glucose control programs

The American Diabetes Association (ADA) recommends

HbA1c Recommended Testing Frequency:

At least twice a year in patients with stable and satisfactorily controlled blood glucose


  • For those with unsatisfactory blood glucose control and need to adjust their regimen, testing should be done once every 3 months or so

  • For pregnant women with diabetes mellitus treated with insulin, a test once every 2 months is recommended.

  • For women with diabetes who are planning to become pregnant, glycosylated hemoglobin should be measured once a month at the beginning;After the blood sugar control is satisfactory, the test can be changed to once every 6-8 weeks until conception.


*Product images are for illustrative purposes only and may differ from the actual product.  Goldsite Diagnostics Inc. reserves the right to change the packaging design at anytime.

See Goldsite's latest trend on social media.

Goldsite Diagnostics Inc., founded in 1999, is a leading Chinese diagnostics manufacturer specializing in in-vitro diagnostics devices and reagents.

Quick Links

Product Links

Get in touch

    (+86)-755-26890807

        (+86)-755-26897973
   export@goldsite.com.cn

 

Copyright © 1999- 2023 Goldsite Diagnostics Inc., All rights reserved.  Sitemap